Radon Test Results: How to Read Your pCi/L Report

Radon test results report your home's radon concentration in picocuries per liter (pCi/L), sometimes with a Bq/m³ conversion. Compare the average to 4.0 pCi/L: at or above means mitigate; between 2.0 and 4.0 means consider mitigation or retest long-term; below 2.0 means routine retesting.

How to Read a Radon Test Report

A lab report for a passive kit gives a single averaged pCi/L figure, the test dates, detector type, and sometimes a measurement uncertainty range. Continuous monitor reports add hourly readings and device calibration information. Focus on the average, not individual spikes — short-term radon varies with weather, barometric pressure, and house pressurization, so an hourly chart that peaks overnight is normal. The comparison points are the EPA action level of 4.0 pCi/L and WHO's 2.7 pCi/L reference.

What to Do at Each Result Level

  • Above 10 pCi/L: very high; plan mitigation promptly and confirm with a professional CRM test if the initial result came from a short-term kit.
  • 4.0–10 pCi/L: mitigate. Confirm elevated short-term results with a follow-up test or proceed directly to mitigation quotes from certified contractors.
  • 2.0–4.0 pCi/L: consider mitigation, or run a long-term (90+ day) test to establish the annual average before deciding.
  • Below 2.0 pCi/L: no action beyond periodic retesting every few years, after renovations, or after changes to the foundation or HVAC.

Common Reasons Results Are Skewed or Wrong

Interpreting a result requires trusting the measurement. Results can run artificially low or high when:

  • Windows or exterior doors were open during a short-term test
  • The detector sat on a windowsill, near a draft, or directly on the floor
  • The kit was mailed weeks after collection, letting charcoal decay or saturate
  • Extreme weather (storm, deep freeze) ran during a short 48-hour test
  • A monitor was uncalibrated or freshly moved from another location

If any of these apply, retest before acting on mitigation decisions.

Common Questions

Should I retest after a mitigation system is installed?

Yes. A post-mitigation test within 30 days of installation (with the system running) verifies performance, and long-term testing afterward confirms the annual average. Most mitigation contractors include a follow-up test; a retest is also warranted after any system downtime or major home remodeling.

My two tests gave different numbers — which is right?

Both may be partially right. Radon fluctuates daily and seasonally, so short-term tests can legitimately differ by a factor of two or more. When results straddle the 4.0 pCi/L boundary, run a long-term test or a simultaneous dual-device measurement to establish the true annual average.

Is your home making you sick?

Take the free 2-minute air quality quiz.

Check →

Indoor air is 2-5× more polluted than outdoors. (EPA)

Test your home before your family breathes another day.

Scan Free →

Stay safe

Track it. Fam keeps safety checklists, maintenance schedules, and your whole household organized. Free.

·