Radon Test Preparation: Steps to Take Before You Test
Close all external windows and doors at least 12 hours before a short-term radon test and keep them closed for the entire test period. Run heating and ventilation systems normally, and avoid whole-house fans, fireplaces, and humidifiers that alter air exchange.
Closed-building conditions explained
Radon measurements only reflect true occupancy exposure when the building is kept closed for the measurement window. External windows and doors must be shut except for normal entry and exit, beginning at least 12 hours before the detector is placed and continuing until the test ends. Normal operation of furnaces, boilers, and mechanical ventilation systems should continue, because radon levels you measure should reflect how you actually live in the property. In the UK, Public Health England guidance mirrors this protocol for both short-term and longer three-month tests.
What to avoid during the test
Several activities disrupt airflow and can distort readings in either direction. For the full duration of the test, avoid the following:
- Whole-house fans, window fans, and evaporative coolers that draw in outside air
- Fireplaces and wood stoves, unless they are your primary heat source
- Humidifiers, dehumidifiers placed near the detector, and clothes dryers vented indoors
- Moving, covering, or touching the detector itself
- Large renovation or demolition work that opens up floors or walls
Where and how to place the detector
Place the detector in the lowest regularly occupied room, typically a living room or bedroom on the ground floor or in a basement. Position it at least 50 cm from external walls, one metre from windows and doors, between 0.8 m and 2 m from the floor, and away from direct sunlight, heat sources, and draughts. Do not place detectors in kitchens, bathrooms, laundry rooms, cupboards, or hallways, because humidity and air turbulence skew results. If you are testing to inform a mitigation decision, some protocols also call for a simultaneous measurement in a high-use upstairs room.
Timing and season considerations
Short-term tests run for as little as 48 hours to seven days, but radon fluctuates significantly with weather and season. For a screening result, run the detector during closed-house winter conditions where possible, when levels tend to peak. A three-month test using two passive detectors is the more reliable method and is the approach recommended by UK public health authorities for confirming whether action is needed. Record the start and end dates precisely, since laboratories calculate the average concentration from your exposure dates.
Common Questions
Can I open windows briefly during a radon test?
You can open external doors briefly for normal entry and exit, but windows should stay closed. If a window is left open for an extended period, note it and consider restarting the test, because the reading will likely underestimate your usual exposure.
Do I need to prepare differently for a basement test?
Basement tests use the same closed-building rules, but the detector should sit in the basement area you actually use. If the basement is unoccupied and unrenovated, test the lowest livable floor instead, and remember that basement readings are typically the highest in the building.
How long should closed-building conditions last?
Begin at least 12 hours before the test starts and maintain them for the whole measurement period. For three-month detectors, live normally; you do not need to keep the house sealed for the entire winter, as the long averaging time smooths out daily variation.