Radon Test and Mitigation: From Measurement to Fix
Testing establishes your indoor radon level; mitigation reduces it. The EPA action level is 4.0 pCi/L, and the most common fix is an active soil depressurization system, which typically lowers radon by 50 to 99 percent. Testing should be repeated after installation to confirm the system works.
Step 1: Test before you mitigate
Never install a mitigation system based on guesswork. A short-term test of 2 to 7 days under closed-house conditions, or preferably a long-term test of 90-plus days, establishes whether mitigation is warranted. Results at or above 4.0 pCi/L warrant action; results between 2.0 and 3.9 pCi/L warrant consideration, since no radon level is risk-free.
Step 2: Choose the mitigation approach
Active soil depressurization (ASD) is the standard technique for homes with basements or slabs. A fan draws soil gas from beneath the foundation and vents it above the roofline. Variants include sub-slab depressurization, drain-tile depressurization, sub-membrane depressurization for crawlspaces, and block-wall depressurization for hollow-block foundations.
- Sub-slab: pipe inserted through the slab, most common
- Sub-membrane: sealed plastic sheet over exposed dirt crawlspaces
- Drain-tile: piggybacks on existing perimeter drains
Step 3: Post-mitigation verification
A confirmation test should be run 24 hours after the system has been running continuously, and no sooner than 24 hours after activation. Most ASD systems reduce radon below 2.0 pCi/L. If post-mitigation levels remain elevated, the installer should check fan performance, suction point placement, and foundation sealing, and may add a second suction point.
What mitigation does not cover
Mitigation systems address soil gas entry, not radon in well water. If your water comes from a private well and radon in water is a concern, a granular activated carbon unit or aeration system treats the water supply separately. Mitigation also does not eliminate the need for periodic retesting; fans fail over time and foundation conditions change.
Common Questions
How much does radon mitigation reduce levels?
A properly installed active soil depressurization system typically reduces indoor radon by 50 to 99 percent. Most homes reach below 2.0 pCi/L after installation. A post-mitigation test confirms actual performance.
Can I test and mitigate in the same week?
A short-term test can identify a problem within days, but mitigation design depends on accurate readings and foundation type. Confirming elevated levels with a second short-term or long-term test is wise before committing to a permanent system.